Health & Safety
Critical Applications of Eclipse® 705 Transmitter
Apr 13 2011
The Eclipse® 705 from Magnetrol (Belgium) is type approved for steam drums, EN 12952-11 (water tube boilers) and EN 12953-9 (shell type boilers) as “primary safety” and “secondary safety”. Combined with a 7MS probe the device can be used in saturated steam applications at a pressure of 155 bar at an equivalent temperature of 345°C.
Additional diagnostic tools allow the user to integrate this transmitter into highly demanding safety instrument loops. With a Safe Failure Fraction (SFF) of 91% the device scores amongst the highest – if not the highest – safety levels.
It is possible to install two or even three Eclipse® devices on one external cage for specific applications. Even when installing only two devices in one cage a SIL3 safety level can be obtained. Adding a third device to the same cage assures continuity to the production process. The three obtained individual level signals increase the overall reliability.
Digital Edition
IET 34.2 March 2024
April 2024
Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...
View all digital editions
Events
May 13 2024 Munich, Germany
May 15 2024 Lund, Sweden
May 15 2024 Frankurt-am-Main, Germany
May 20 2024 Columbus, OH, USA
May 21 2024 Lagos, Nigeria