Elemental Analysis of Sulfur, Calcium and Metals in Crude Oil by EDXRF

Nov 15 2017

Background

Sulfur (S), vanadium (V) and nickel (Ni) occur naturally in crude oil, and their concentrations vary depending on the geographical region of the oil deposits. Depending on the region some crude may also contain measurable levels of calcium (Ca) and iron (Fe). High metal content can adversely affect the refining process during cracking, making crude oil with low levels of vanadium and nickel more desirable. Excess levels must therefore be removed before refining.

At the refinery, midstream in pipelines and at gathering points, a quick and easy means of screening and monitoring vanadium and nickel levels is essential for characterising the quality of the crude before refining.

Elemental Analysis by Energy Dispersive X-ray Fluorescence (EDXRF) is a valuable tool used to meet this industry analytical need. EDXRF spectrometers are elemental analysis tools of choice for many applications due their small size, simple design and low operating cost. For the petroleum industry, EDXRF offers rapid elemental analysis of chlorine, lead, sulfur and metals in crude, oils, gasoline, fuels, lubricants and waste materials.

Analysis

Each oil sample was homogeneous and stable. For the data collection, 31mm diameter XRF sample cups were filled 75% full (approx. 4g) and measured directly. A Rigaku NEX DE spectrometer was employed for data collection and reduction. Counting time of 700 seconds was used for all measurements.

For this example, empirical calibrations were built using a suite of 10 commercially available mineral oil calibration standards that represent crude oil. Table 1* gives the calibration results and demonstrates that good fits were achieved. *(Please refer to image A)

To demonstrate measurement precision, ten repeat analyses of a blank mineral oil sample were taken with the sample in static position, and the standard deviation (σ) determined. For the purpose of this example, the Lower Limit of Detection (LLD) was defined as 3σ. As shown in Table 2*, LLDs below 1 ppm were achieved for calcium, vanadium and nickel. Increasing the measurement time could further lower detection limits. *(Please refer to image B)

Conclusion

Modern EDXRF spectrometers give technical and non-technical operators alike a simple yet powerful and versatile system for quantifying multi-elemental composition using the empirical approach. The results indicate that given stable samples, proper sample handling and calibration technique, energy dispersive X-ray fluorescence achieves excellent performance for monitoring sulfur, calcium and metals in oil.


Digital Edition

PIN 25.1 Feb/March

March 2024

In This Edition Safety - The technology behind the ION Science Tiger XT - Safety with ammonia and LOHCs as hydrogen carriers Analytical Instrumentation - Discussion on new tribology te...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

Saudi Plastics and Petrochem

May 06 2024 Riyadh, Saudi Arabia

View all events